EyeC ProofRunner buttons and shortcuts

The following buttons and menu items are relevant for the inspection process. When applicable, corresponding shortcuts are listed.

Table 1. EyeC ProofRunner buttons and menu items
Button Name Description Shortcut
Machine stop button Manual control of web drive

Prevents the machine from automatically stopping when a suspicious area is found.

Stop machine button Stop Stops the machine in any position. 0 (num pad)
Start machine slow button Jog Starts the machine at low speed.
Run button Run Starts the machine at high speed.
Go to suspicious area to handle button

Show suspicious area

Navigates to the suspicious area that caused the machine to stop.

Previous suspicious area button

Previous suspicious area

Navigates to the previous suspicious area.

Left arrow key [Left arrow]
Next suspicious area button Next suspicious area Navigates to the next suspicious area, even if the previous one has not been graded. Right arrow key [Right arrow]
Undo button Undo suspicious area grading Resets the grading of suspicous areas.
Grade as good button

Grade suspicious area as “good”

Grades the suspicious area as “good” (= acceptable).

[+]
Set item replaced button

Grade suspicious area as “replaced defect”

Reports a defect tag exchange. [-]

Grade suspicious area as “ungraded”

Leaves a suspicious area ungraded; there is no corresponding button or shortcut.

Readapt to current printout button

Readapt to current printout

Readapts the reference image (golden image) to the current repeat.

Inspection section handling

Register new section (roll, pallet, etc)...

Registers a new section (for example, roll change; see Roll).

Report button Stop inspection / create report...

Opens a dialog that offers options of stopping the inspection and creating different types of reports. Alternatively, this is done automatically by a new set-up of the machine.

[Ctrl]+[F]