Every measurement region consists of 2 areas that are used to stabilize the
measurement. Each region has an anchor point to define the start and the end point
of the measurement. You can measure distances in the following ways:
Horizontally
Vertically
Horizontally and vertically
Euclidean
To set up measuring regions, select the double arrow.
See following figure. Figure 1. Setting up distance measuring (in this figure shown on a
carton)
Span 2 rectangles by using your mouse.
When the 2 rectangles have been spanned, a dialog opens for you to set up the
initial values of the measurement.
Choose the measure method and a tolerance value (in mm) and click
OK.
The region is created. The suitability is shown next to the regions. A
green number indicates a very suitable value. A dark red number indicates a not
suitable value. If you have set up regions for
distance measurement, during the inspection the actual value for each
distance measurement is displayed in the special region list below the image
of the inspected sample.If the distance measurement is out of bounds, it is
marked orange. You can even adapt the thresholds of the measuring during an
inspection by clicking at the item with your right mouse
button.
Figure 3. The suitability is displayed in colors from green (good) to red
(poor)
Figure 4. Actual value for distance measurement during the inspection
To delete a special area, right-click its marking square and select
Delete